Softeners Jupiter removal of total hardness
APPLICATIONS
The process of water softening (removal of total hardness - TH) by the means of
ion-exchange resin is the way to remove salts of calcium and magnesium that
may form calcareous encrustations.
The installation of a softener is recommended to avoid encrustations into pipelines
and on domestic and industrial water heating appliances, to save energy
and thermal efficiency.
Jupiter softeners can be provided on request with manual by-pass to mix the
softened water with raw water to comply with any required level of residual total
hardness.
Domestic use: anti-scale protection of pipes, taps, boilers, heating systems,
washing machines, and other installations.
Technical use: all applications when removal of total hardness is required.
Remark - Use a pre-filter to protect the softener; use a polyphosphate dosing
system downstream the softener to avoid any corrosive action due to softened
water.
SPECIFICATIONS
Non-toxic materials, suitable for drinking water.
Control-valve: NORYL.
Tank: glass-fibre reinforced polyethylene.
Brine tank and cabinet: polyethylene.
Treating material: strong cationic ion-exchange resin (Na cycle).
Regeneration: exhausted resin is automatically regenerated by
a saturated solution of NaCl (brine).
Remark – material for regenarion (NaCl) not provided with the
softener.
WORKING CONDITIONS
Max working pressure: 6 BAR
Min working pressure: 2 BAR
Max working temperature: 50°C
Max concentration Fe: 0,1 ppm
Max concentration free Cl: 0,5 ppm
|
 |